A New Design of Large-format Streak Tube with Single-lens Focusing System

Published Online: 26 Oct 2021
Page range: 191 - 196
Received: 05 Jul 2021
Accepted: 19 Oct 2021
Journal Details
License
Format
Journal
First Published
07 Mar 2008
Publication timeframe
6 times per year
Languages
English
Abstract

Streak tubes with large-format and high spatial resolution are central to mm-spatial-resolved STIL detection system and hyperspectral resolved ICF experiment. In this paper, we established a large-format streak tube with a three-coaxial-cylindrical single-lens focusing system, a spherically curved photocathode and phosphor screen model in CST Particle Studio. The temporal and spatial resolution were calculated and mimicked based on the Monte-Carlo sampling method in static and dynamic mode. The simulated results show that the static spatial resolution reaches 50 lp/mm over the whole 50 mm effective photocathode length, and the physical temporal resolution is better than 45 ps. Furthermore, in dynamic working mode, the streak tube can achieve spatial resolution of 10 lp/mm and temporal resolution of 60 ps. The simulation results will be used to guide the design and production for large-format with high spatial resolution streak tube development.

Keywords

[1] Xia, W., Han, S., Ullah, N., Cao, J., Wang, L., Cao, J., Cheng, Y., Yu, H. (2017). Design and modeling of three-dimensional laser imaging system based on streak tube. Applied Optics, 56 (3), 487-497.10.1364/AO.56.000487 Search in Google Scholar

[2] Ye, G., Fan, R., Lu, W., Dong, Z., Li, X., He, P., Chen, D. (2016). Depth resolution improvement of streak tube imaging lidar using optimal signal width. Optical Engineering, 55 (10), 103112.10.1117/1.OE.55.10.103112 Search in Google Scholar

[3] Macphe, A.G., Dymoke-Bradshaw, A., Hares, J.D., et al. (2016). Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited). Review of Scientific Instruments, 87 (11), 420-568.10.1063/1.4960376 Search in Google Scholar

[4] Howorth, J.R., Milnes, J.S., Fisher, Y., Jadwin, A., Boni, R., Jaanimagi, P.A. (2016). The development of an improved streak tube for fusion diagnostics. Review of Scientific Instruments, 87 (11), 287-294.10.1063/1.4964894 Search in Google Scholar

[5] Shchelev, M.Y., Andreev, S.V., Greenfield, D.E., Degtyareva, V.P., Kopaev, I., Monastyrskiy, M. (2015). On some limitations on temporal resolution in imaging subpicosecond photoelectronics. Quantum Electronics, 45 (5), 455-461.10.1070/QE2015v045n05ABEH015775 Search in Google Scholar

[6] Hui, D., Tian, J., Lu, Y., Wang, J., Wen, W., Liang L., Chen, L. (2016). Temporal distortion analysis of the streak tube. Acta Physica Sinica, 65 (15), 158502. Search in Google Scholar

[7] Tian, L., Shen, L., Li, L., Wang, X., Chen, P., Wang, J., Chen, L., Zhao, W., Tian, J. (2021). Small-size streak tube with high edge spatial resolution. Optik, 242, 166791.10.1016/j.ijleo.2021.166791 Search in Google Scholar

[8] Hui, D., Luo, D., Tian, L., et al. (2018). A compact large-format streak tube for imaging lidar. Review of Scientific Instrument, 89 (4), 045113.10.1063/1.5024269 Search in Google Scholar

[9] Tian, L.-P., Li, L.-L., Wen, W.-L., Wang, X., Chen, P., Lu, Y., Wang, J.-F., Zhao, W., Tian, J.-S. (2018). Numerical calculation and experimental study on the small-size streak tube. Acta Physica Sinica, 67 (18), 188501. Search in Google Scholar

[10] Ageeva, N.V., Andreev, S.V., Belolipetski, V.S., et al. (2009). Small-size meshless 50 ps streak tube. In 28th International Congress on High-speed Imaging and Photonics. SPIE, 71260A. Search in Google Scholar

[11] Feldman, G.G., Jilkina, V.M., Razdobarin, G.T. (1998). PV-400 picosecond streak tube with large format photocathode. Optical Engineering, 37 (8), 2247-2248. Search in Google Scholar

[12] Tian, L.-P., Wen, W.-L., Wang, X., Chen, P., Hui, D.-D., Lu, Y., Tian, J.S., Zhao, W. (2019). Research on the spatio-temporal and gain performances on the small-size streak tube. Acta Photonica Sinica, 48 (7), 723002. Search in Google Scholar

[13] Feng, J., Shin, H.J., Nasiatka, J.R., et al. (2007). An xray streak camera with high spatio-temporal resolution. Applied Physics Letters, 91 (13), 134102.10.1063/1.2793191 Search in Google Scholar

[14] Shakya, M.M., Chang, Z. (2005). Achieving 280 fs resolution with a streak camera by reducing the deflection dispersion. Applied Physics Letters, 87 (4), 111.10.1063/1.2001732 Search in Google Scholar