Matrix FMEA analysis with cause-effect diagram for selected fluid power component


Zitieren

This paper presents an application of matrix FMEA analysis and cause-effect diagram for a double acting hydraulic cylinder. A decomposition of the investigated cylinder has been made and main functions and potential failures for the pair-function relation have been identified. Elements with the greatest probability of failure and cause-effect relationship have been determined.